Name of indicators |
Indicator |
|
Boiler rated heat output, kW |
3500 |
|
Boiler minimum heat output, kW |
1000 |
|
Estimated type of fuel (wood chips, sawdust) GOST 33103.1-2014 — relative moisture, % — calorific value, MJ/kg (kcal/kg) — fuel consumption, kg/h |
P46A 60 5,7(1360)* 3430* |
|
Efficiency, up to % |
80* |
|
Design pressure, MPa (kgf/cm2) |
0,6 (6,0) |
|
Rated heat carrier flow temperature at the boiler inlet, °C |
220 |
|
Rated heat carrier flow temperature at the boiler outlet, °C |
260 |
|
Minimum permissible heat carrier flow rate, m3/h |
125 |
|
Maximium permissible heat carrier flow rate, m3/h |
166 |
|
Maximum heat carrier flow temperature, °C |
280 |
|
Exit gas temperature (max), °C |
300* |
|
Draught loss, Pa |
750* |
|
Rated voltage of a system, V |
380 |
|
Installed electric power, kW |
29,9 |
|
Boiler weight (dry), kg Furnace weight, kg Heat exchanger weight, kg Afterburning chamber weight, kg |
53000 19200 12500 21500 |
|
Boiler overall dimensions, mm: Length (L) Width (W) Height (H) |
6560 3530 7850 |