Name of indicators |
Indicator |
Boiler rated heat output, kW |
4000 |
Boiler minimum heat output, kW |
1200 |
Estimated type of fuel (wood chips, sawdust) GOST 33103.1-2014 - relative moisture, % - calorific value, MJ/kg (kcal/kg) - fuel consumption, kg/h |
P46A 60 5,7(1360)* 3300* |
Efficiency, up to % |
86* |
Design pressure, MPa (kgf/cm2) |
0,6 (6,0) |
Rated heat carrier flow temperature at the boiler inlet, °C |
70 |
Rated heat carrier flow temperature at the boiler outlet, °C |
95 |
Minimum permissible heat carrier flow rate, m3/h |
137,3 |
Maximum heat carrier flow temperature, °C |
110 |
Minimum heat carrier flow temperature, °C |
70 |
Exit gas temperature (max), °C |
150* |
Сombustion products oxygen content, % |
7,5 |
Installed electric power, kW |
29,9 |
Boiler weight (dry), kg Furnace weight, kg Heat exchanger weight, kg Afterburning chamber weight, kg |
53000 19200 12500 21500 |
Boiler overall dimensions, mm: Length (L) Width (W) Height (H) |
6560 3530 7850 |